Landlord electrical
safety (EICR).
England & UK · 5-year EICR rules, C1/C2/FI 28-day deadlines & PRS database checks
Private landlords in England must have the fixed electrical installation inspected and tested at least every 5 years by a qualified person, producing an Electrical Installation Condition Report (EICR). Since mandatory 5-year inspections began in 2020/21, thousands of tenancies hit their first 5-year renewal in 2025–2026. If your report flags a C1, C2 or FI code, you have at most 28 days to complete the repair and send written confirmation to your tenant and local council.
Calculate your EICR deadlines ↓EICR 28-day remedial & 5-year
renewal date calculator.
Enter your EICR inspection date and the highest observation code recorded on the report to check your statutory deadlines in England.
What C1, C2, FI and C3
mean on your report.
Your EICR is marked either Satisfactory or Unsatisfactory based on the observation codes in Section K / the observations schedule.
| Observation code | Overall EICR result | What it means & what you must do |
|---|---|---|
| C1 · Danger present | Unsatisfactory | Immediate risk of injury (e.g. exposed live wires, broken socket faceplate exposing live parts). The electrician should make it safe before leaving the property; remedial repair must be completed within 28 days (or shorter if specified). |
| C2 · Potentially dangerous | Unsatisfactory | Not immediately live to the touch, but could become dangerous under fault conditions (e.g. absence of RCD protection on sockets, poor earthing/bonding, overloaded circuits). Must be remedied within 28 days (or shorter if specified). |
| FI · Further investigation required | Unsatisfactory | The inspector could not fully verify safety (e.g. an unlabelled circuit or hidden junction box showing low insulation resistance). Must be investigated and resolved within 28 days—an EICR with an FI code is legally unsatisfactory. |
| C3 · Improvement recommended | Satisfactory | The installation does not meet the latest edition of BS 7671 wiring regulations in every respect, but is still safe for continued use. You do not legally have to carry out C3 work for the report to be satisfactory. |
Four statutory deadlines
for sharing the EICR.
Under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, failing to carry out the inspection, complete remedial work or supply copies can carry a council civil penalty of up to £30,000 (increasing to up to £40,000 under the Renters' Rights Act enforcement framework).
- 1. Existing tenants: 28 daysGive a copy of the EICR to every existing tenant within 28 calendar days of the inspection date.
- 2. New tenants: before move-inGive the latest satisfactory EICR (plus any remedial certificates) to a new tenant before they occupy the property.
- 3. Council request: 7 daysIf your local housing authority requests the EICR in writing, you must supply it within 7 calendar days.
- 4. Remedial proof: 28 daysAfter C1/C2/FI remedial work is finished, send the electrician's written confirmation and the original report to the tenant and the local council within 28 days.
EICR vs EIC and England’s
new Landlord Register.
The October 2026 GOV.UK guidance for England's Private Rented Sector (PRS) Database explains which electrical documents are accepted when registering a rental from 15 December 2026.
When an EIC replaces an EICR
If your property is a new build or has had a full electrical rewire within the last five years, you will hold an Electrical Installation Certificate (EIC) rather than an EICR. Both the Electrical Safety Regulations and the PRS Database accept a valid EIC for the first 5 years from installation, after which you commission your first 5-year EICR.
How to check your electrician
Always verify that your inspector belongs to a government-approved competent person scheme (such as NICEIC or NAPIT) on the official Electrical Competent Person Register—make sure you select "Electrical safety report (EICR)" rather than installer-only domestic work.
Are 5-year EICRs mandatory in Scotland, Wales and Northern Ireland too?
Yes—all four UK nations now require 5-yearly periodic electrical inspections in private rentals. Scotland requires a 5-year EICR plus Portable Appliance Testing (PAT) on landlord-supplied movable appliances; Wales requires a 5-year Periodic Inspection Report (PIR/EICR) under the Fitness for Human Habitation rules; Northern Ireland introduced mandatory 5-year EICRs under the Electrical Safety Standards Regulations (Northern Ireland) 2024.
Does the 5-year EICR cover portable appliances like a fridge or washing machine?
The statutory 5-year EICR in England covers the fixed electrical installation (wiring, consumer unit/fusebox, sockets, switches and fixed light fittings). GOV.UK recommends visually checking and PAT-testing any portable electrical appliances you supply as part of the tenancy, and recording their condition on your check-in inventory.
How do EICRs connect to the 21 HHSRS hazards?
Hazard 17 of the HHSRS checklist covers electrical hazards, and Hazard 18 covers fire safety. Keep your EICR alongside your annual Gas Safety Record (CP12) and EPC.
Check the official guidance
Keep the EICR and remedial certificates together.
Store the 5-year electrical report and any Minor Works certificates with the rental so you can see when the next inspection is due.


50founding places
No.01of 50 · next place available
No.is yours. Your first year is free at launch.
Keep in touch.Join for development and launch updates.
Your free year starts at launch.
Email hello@sprout-let.co.uk to join the list.
Want to talk about the app? Say hello.
Know a landlord who would like to join? Share the founding offer
Places follow signup order from 29 September 2026, one per email address.