SproutletGet your ticketJoin the list

Landlord gas safety
certificate.

England, Wales & Scotland · CP12 verification checklist, 2-month window & EICR schedule

Every gas appliance, pipe and flue you provide in a rental must be checked every 12 months by a Gas Safe registered engineer. You must keep the Landlord Gas Safety Record (commonly called a CP12) for at least two years and give existing tenants their copy within 28 days—or before a new tenant moves in. Use the 9-point CP12 verification checklist and access templates below.

Jump to 9-point CP12 checklist ↓
By Lewis Danks at SproutletChecked Official HSE & GOV.UK sources ↓

Your statutory gas
safety duties.

The Gas Safety (Installation and Use) Regulations 1998 apply across England, Wales and Scotland (with parallel rules in Northern Ireland).

DutyWhat the law requires
Annual 12-month checkEvery gas appliance (boiler, hob, cooker, gas fire) and flue you provide must be inspected at intervals of no more than 12 months.
Gas Safe accreditationThe engineer must hold a current Gas Safe registration covering the specific work categories (e.g. CCN1 core domestic gas, CENWAT for boilers, CKR1 for cookers).
28 days / before move-inGive existing tenants a copy within 28 calendar days of the check. New tenants must receive a valid copy before they occupy the property.
Tenant’s own appliancesIf a tenant brings their own gas cooker, you are not responsible for safety-checking the appliance itself, but you remain legally responsible for the fixed installation pipework and any flue serving it.
Carbon monoxide alarmsIn England and Wales, a working carbon monoxide alarm is required in every room used as living accommodation that contains a fixed combustion appliance (excluding gas cookers). In Scotland, CO alarms are required in every room with a carbon-fuelled appliance (including gas cookers) or a flue.

Book up to 2 months early
without losing your renewal date.

Waiting until the last week of your certificate leaves no margin if the tenant is on holiday or the boiler needs a spare part.

How Regulation 36(3) works (MOT-style)

Since 2018, Regulation 36(3) allows you to carry out the annual gas safety check in Months 10 to 12 (up to two calendar months before the current expiry date) while keeping the original expiry anniversary.

Example: If your current CP12 expires on 14 September 2026, you can have the engineer inspect any time between 15 July 2026 and 14 September 2026, and your next deadline will still be 14 September 2027.

How long to keep early-check records

Normally you must retain each Gas Safety Record for at least two years.

If you use the two-month early window, you must keep that record until two further annual checks have been completed so you can prove the unbroken chain of preserved dates.

The 9-point CP12
verification checklist.

Why is it called a CP12? "CP12" comes from the old Corgi Proforma 12 paper pad. Today the legal name is a Landlord Gas Safety Record. Before you file the PDF or pay the invoice, check that all nine items below are present.

Checklist itemWhat to verify on the record
01 · Engineer’s name, signature & Gas Safe IDConfirm the 7-digit Gas Safe registration number and check on gassaferegister.co.uk that the engineer is qualified for every appliance type inspected (e.g. boiler, gas hob, gas fire).
02 · Full rental property address & landlord detailsThe exact address of the let property and the name and address of the landlord (or managing agent where applicable).
03 · Date of the inspectionThe exact date the check was carried out—your 28-day window to give the tenant their copy starts from this date.
04 · Every gas appliance & flue listedDescription and location of each landlord-provided appliance (boiler, cooker/hob, fire) and every flue/chimney checked, including flues in roof voids.
05 · Operating pressure & safety device resultsConfirmation that operating pressure/heat input, burner combustion, ventilation and flame-supervision devices were tested.
06 · Any defects identified & remedial actionClear statement of any defect found (such as Immediately Dangerous [ID] or At Risk [AR]) and the remedial action taken or warning notice issued.
07 · Carbon monoxide & smoke alarm checkMany engineers record alarm presence and test results on the CP12—in England, a CO alarm is mandatory in any room with a fixed combustion appliance (excluding gas cookers).
08 · Next due date (including Regulation 36(3) preservation)If the check was done up to 2 months early under Regulation 36(3), confirm the record shows the preserved 12-month anniversary date.
09 · Dated proof of handover to every tenantSave the date and method (email or signed paper receipt) you gave the certificate to existing tenants (within 28 days) or new tenants (before move-in).

5-year EICR rules, EPCs
and tenant access refusal.

Keep your four core property safety dates—Gas Safety (CP12), Electrical (EICR), EPC and Smoke/CO alarms—in one schedule, and know what to do if a tenant fails to grant access.

Certificate / checkMaximum interval (England)When to give the tenant a copyKey compliance rule
Gas Safety Record (CP12)Every 12 monthsWithin 28 days of check; before move-in for new tenantsBook in Months 10–12 to preserve your annual renewal date.
Electrical report (EICR)At least every 5 yearsWithin 28 days of inspection; before move-in for new tenants (or within 28 days of request)Any C1, C2 or FI (Further Investigation) code makes the EICR unsatisfactory and must be remedied within 28 days (or sooner if specified), with written confirmation sent to the tenant and council within 28 days.
Energy Performance Certificate (EPC)Every 10 years (when let)Before marketing / before tenancy startsMinimum rating E required now (unless a valid exemption is registered). See our EPC for landlords guide.
Smoke & CO alarm testDay 1 of every new tenancy (and routine visits)Record on check-in inventoryOne smoke alarm on every habitable storey; one CO alarm in every habitable room with a fixed fuel-burning appliance (excluding gas cookers in England/Wales). Log tests on our check-in inventory.

What if the tenant doesn’t allow access?

The HSE requires landlords to take "all reasonable steps" to arrange the gas safety check, and never to force entry without court authorisation. Start 6 to 8 weeks before expiry and send three polite written requests (keeping copies of every message), explaining that the check is for their safety and a legal duty.

Copy-paste access request message

“Hi [Tenant Name], our annual Gas Safe check at [Property Address] is due before [Expiry Date]. [Engineer Name] (Gas Safe Reg #[Number]) has slots available on [Date 1] or [Date 2] and only needs about 30 minutes to test the boiler and hob. Could you let me know which slot suits you, or if you’d prefer me to meet the engineer there with my spare key? Thanks, [Your Name]”

How do I check an engineer is genuinely Gas Safe registered?

Look up their 7-digit licence number or business name on the official Gas Safe Register and check the back of their ID card on arrival—it lists each specific appliance category (boiler, cooker, fire, LPG) they are qualified to inspect.

How do CP12 and EICR fit with England’s new Landlord Register?

Under England's PRS Database rollout from 15 December 2026, you must provide details of your current Gas Safety Record, EICR and EPC within 28 days of registering the property. Check your regional deadline in our landlord register guide, and see the wider 21-point hazard rules in our HHSRS checklist.

Check the official guidance

Find the certificate. See the next check.

Keep the gas safety record with the rental and see when the next check is due.

Sproutlet’s Properties screen, with rent, compliance and maintenance for the selected rental.
Explore the app
Sproutlet with a mug, offering a little help.
Founding landlordSproutlet interest listFirst year freeLaunch updates

50founding places

No.01of 50 · next place available

No.is yours. Your first year is free at launch.

Keep in touch.Join for development and launch updates.

Your free year starts at launch.

Places follow signup order from 29 September 2026, one per email address.